Home
> Services > SCR
and Catalyst Management >
Testsing
SCR-Tech uses the services of certified labs for catalyst testing and
analysis to determine catalyst deactivation causes and provide information
for system optimization and determining the best catalyst regeneration
process required for each client.
Testing includes:
- Bench-scale reactor testing
- SO2/SO3 conversion
rate
- Pressure drop ∆p
- Initial activity K0
- Actual activity K
- XRF/XRD/AAS-analysis
- SEM-analysis
- Chemical and physical properties of
catalyst
- Micro-scale reactor testing
Bench-scale reactor in EnBW’s catalyst testing
laboratory
All testing is done in strict
accordance with the internationally accepted German standard for testing
DeNOx catalyst, “VGB Guideline VGB-R 302 He, 2nd Edition”.
|